Copper Power Cable Suppliers

Home / Products / Power Cable
Hangzhou Linan Jiaheng Cable Co., Ltd.
Who We Are

We Not Only Produce Network Cables. We Make Our Partnership Lasting.

Hangzhou Linan Jiaheng Cable Co., Ltd.
Jiaheng Cable Co., Ltd. is China Custom Copper Power Cable Manufacturers and Flexible Power Control Cable Suppliers , founded on January 23, 2008, with its headquarters located at Heziwu, Linglong Sub‑district, Lin’an District, Hangzhou, Zhejiang Province. With years of in‑depth experience in the cable industry, the company strives to be a global expert in high‑end network cables and digital connection solutions. We offer Low Voltage Power Cables for sale. Upholding the development philosophy of **Precise Connection & Intelligent Manufacturing**, Jiaheng has completed industrial upgrading and transformation. Evolving from initial coaxial cable production, it has grown into a specialized enterprise integrating the R&D, manufacturing, and sales of network cables...
View More
Hangzhou Linan Jiaheng Cable Co., Ltd.

Corporate Vision

To serve as the "nerve fibers" of the global digital world, enabling every data center, every building and every household to run on Jiaheng cables.
OUR PRODUCTS ARE SOLD BOTH DOMESTICALLY AND INTERNATIONALLY, HELPING TO DRIVE INDUSTRY UPGRADES. OUR PRODUCTS ARE SOLD BOTH DOMESTICALLY AND INTERNATIONALLY, HELPING TO DRIVE INDUSTRY UPGRADES.
News

Keep Up To Date With Our Latest News.

View More
Power Cable Industry knowledge

Jiaheng Cable Co., Ltd. is a China-based production company for flexible power and control cables, and this product family is our Custom Flexible Power Control Cable range. It covers light-duty flexible power cables for equipment supply, control circuits and low-voltage distribution connections in switchgear assembly, machinery, security installations and building electrical work.

Our standard programme is the RVV and RVVP series to JB/T 8734. R denotes multistrand fine copper conductors, V denotes PVC insulation, the second V denotes a PVC sheath, and P denotes copper wire braid screening. The flexible conductor gives good bend performance for panel wiring and repeated movement, while the PVC insulation and sheath provide electrical insulation plus abrasion and oil resistance.

Power Cable Range: RVV and RVVP

The family is supplied in core counts from 2 to 24 and nominal cross-sections from 0.5 mm² to 2.5 mm². Unscreened RVV handles power delivery and hard-wired control; screened RVVP carries control and signal circuits where VFD output, contactor coils or motor feeders are present.

RVV Unshielded Flexible Power and Control Cable

Used for power delivery and hard-wired control circuits where no screen is required. Typical duties include switchboard and panel internal wiring, feeds to motors, pumps, fans and compressors, security system power, lighting distribution and building services.

RVV 2 Core 2.5mm² Flexible Copper PVC Control Power Cable 300/500V

RVVP Shielded Flexible Control Cable

Adds a copper wire braid screen for control and signal circuits in electrically noisy environments. Suited to PLC-to-I/O wiring, VFD control circuits, access control, intercom, instrumentation and building management systems.

RVVP 4 Core 1.0mm² Shielded Flexible Control Cable with Copper Braid Screen

Where Each Type Fits

The selection between RVV and RVVP depends on whether the same cable carries only power, or power together with control or feedback signals near interference sources.

Cable type Core / section range Rated voltage Best for Typical circuits
RVV 2×2.5mm² 2 cores / 2.5 mm² 300/500 V Power delivery and hard-wired control Switchboard wiring, motor and equipment feeds, security controllers
RVV series 2–24 cores / 0.5–2.5 mm² 300/300 V or 300/500 V Equipment supply and low-voltage distribution Panel internal wiring, building services, lighting and general equipment connections
RVVP 4×1.0mm² 4 cores / 1.0 mm² 300/500 V Control plus signal in EMI-prone installations PLC to remote I/O, VFD control, CCTV and access control wiring
RVVP shielded series 2–24 cores / 0.5–2.5 mm² 300/300 V or 300/500 V Screened control and signal circuits Automation equipment, security systems, instrumentation, intercom and PA wiring

Construction and Critical Specifications

Representative data from our RVV and RVVP lines:

  • Rated voltage: 300/300 V or 300/500 V depending on construction; our RVVP 4×1.0 mm² is listed at 300/500 V.
  • Core count and section: 2 to 24 cores, 0.5 mm² to 2.5 mm².
  • Conductor: bare copper stranded construction; RVV 2×2.5 mm² uses 48×0.245 mm, RVVP 4×1.0 mm² uses 32×0.2 mm.
  • Screen: RVVP copper wire braid with ≥80% coverage.
  • DC resistance at 20°C: ≤7.98 Ω/km for RVV 2×2.5 mm²; ≤19.5 Ω/km for RVVP 4×1.0 mm².
  • Thermal rating: -20°C to +70°C; maximum conductor temperature 70°C for the standard PVC grade.
  • Reference standard: JB/T 8734 light PVC insulated and sheathed flexible cable.

Configuration and Customisation

Because this is a flexible power control cable family, we build to the circuit and installation requirements rather than offering only fixed stock sizes. The following options are part of the RVV/RVVP programme:

  • Core count and conductor cross-section matched to the load and voltage-drop calculation.
  • Core colour sequence and outer sheath colour for circuit identification.
  • Printing, marking, branding and labelling language for distributor or OEM packaging.
  • Coil or drum lengths matched to site handling and installation planning.
  • Alternative sheath compounds where the cable is exposed to oils, chemicals or continuous flexing; for drag-chain duty we recommend confirming a dedicated flexible-chain cable.
  • Screened constructions with braid coverage and screen design confirmed on the datasheet.

Quality and Project Support from the Company

Jiaheng Cable was founded in 2008 in Hangzhou, Zhejiang, and has grown from coaxial cable production into R&D, manufacturing and sales of network, composite, instrumentation and flexible control cable families. The power cable range runs on the same production and QC discipline as our Ethernet and instrumentation lines.

  • Direct supply relationship: Cables go from our production line to your warehouse, with one English-speaking contact who understands cable construction and answers technical questions directly.
  • Material traceability: Copper purity certificates, insulation compound datasheets and pre-shipment QC reports with photos and test data are available; you review and approve before shipment.
  • OEM-focused supply: We do not compete with your brand in the markets where our partners operate. Your brand, customer base and pricing remain confidential.
  • Flexible MOQ: First orders can be sized to test the market, then scaled with the project.

Installation, Grounding and Maintenance

The stranded conductor terminates cleanly with ferrules or screw terminals and bends easily inside enclosures. For screened RVVP cable, performance depends on correct screen termination.

  • Terminate the braid screen at one end, normally at the cabinet or controller end, using a shield clamp, braided pigtail or EMC gland that makes wide-area contact.
  • Single-ended bonding avoids circulating currents where the ends of the run sit at different earth potentials. Where the specification requires double-ended bonding, provide an equipotential bonding conductor alongside the cable.
  • Protect the circuit with an overcurrent device selected for the installation method, ambient temperature, grouping and run length, and verify voltage drop on long feeds.
  • Periodically inspect the sheath for cuts or chemical exposure, check screen continuity and confirm that termination ferrules remain tight, especially on equipment subject to vibration.

Information We Use to Configure Your Solution

Our proposal is based on the working point and installation conditions. To prepare an accurate configuration and quotation, please send the following:

  • Working voltage and circuit type: power feed, hard-wired control, or control plus signal.
  • Required core count and conductor cross-section.
  • Screened or unscreened construction, and braid coverage where shielded cable is specified.
  • Installation environment: panel, tray, conduit, outdoor exposure, oil or chemical contact, or continuous flexing.
  • Core colour sequence, sheath colour, printing and marking requirements.
  • Length per coil or drum, total quantity and preferred packing.
  • Any project standard or acceptance reference such as IEC, EN, UL or national code requirements.

Related Cable Families

For projects that combine power with analog process signals, our Instrumentation Cable range covers 1, 2 and 4-pair constructions with Al/PET foil screening for 4-20mA loops. Composite cable, Ethernet cable and fire alarm cable are available from the same product platform.

Power Cable FAQ

What is the difference between RVV and RVVP?

RVV is an unscreened flexible PVC power and control cable for power delivery and hard-wired control. RVVP adds a copper wire braid screen around the cores, with ≥80% coverage in our 4×1.0 mm² construction, to reduce EMI coupling. Choose RVVP when a control or feedback circuit runs near VFDs, contactors or motor feeders.

What sizes and ratings are available?

The family covers 2 to 24 cores and 0.5 mm² to 2.5 mm², rated 300/300 V or 300/500 V depending on construction, with a maximum conductor temperature of 70°C. Representative items are RVV 2×2.5 mm² 300/500 V and RVVP 4×1.0 mm² 300/500 V.

How should the RVVP braid screen be grounded?

For normal control circuits, terminate the braid at one end, normally at the cabinet or controller, using a wide-area shield clamp, braided pigtail or EMC gland. If the project specification requires double-ended bonding, provide an equipotential bonding conductor alongside the cable.

Can we get custom colours, printing, lengths and packing?

Yes. Custom core colours, sheath colours, printing and marking, cut lengths, sheath compounds and coil or drum packing are part of our flexible cable offer. We confirm the core colour sequence before shipment so installation records match the cable.

What project information do you need for a quotation?

Working voltage, circuit type, core count and cross-section, screened or unscreened, installation environment, run length, colour sequence, packing and quantity. Any project standard referenced for acceptance should also be included.

What documentation is available before shipment?

For QC and material traceability, we can supply copper purity certificates, insulation compound datasheets and pre-shipment QC reports with photos and test data. You review and approve the documentation before shipment.